chromatography
CC Analytical Services has expertise in all usual chromatographic procedures. All the standard separation systems, colums and detectors are available. This is being extended by the introduction of fast chromatography techniques.
  • Gas chromatography (GC)
  • High performance liquid chromatography (HPLC)
  • Capillary electrophoresis (CE)
  • Ion chromatography (IC)
  • Gel permeation chromatography (GPC)
  • Coupling techniques
    • GC and LC/HR-MS
    • GC and LC/MS
  • liquid
    CC Analytics has almost all the liquid chromatography techniques. A broad range of detectors enables analyses to be optimized for specific substances.
    Types: Detection :
    • High performance liquid chromatography (HPLC)
    • Capillary electrophoresis (CE)
    • Ion chromatography (IC)
    • Gel permeation chromatography (GPC)
    • Thin layer chromatography (TLC)
    • UV absorption (UV)
    • Diode array (DAD)
    • Mass (MS)
    • Refractive index (RI)
    • Conductivity
    • Light scattering (ELSD)
    • Fluorescence detection (FD)
    • Viscosity detection

    Download File

    Please enter your contact details and the file will start downloading immediately after your details have been submitted. This only has to be done for the first file you download on this site. Thank you for your understanding.

    Personal Information

    Dr. Andreas Grimm
    Dr. Andreas Grimm
    CCA, Chromatography
    +49 69 305 5797

    Request to Clariant

  • gas

    CC Analytical Services uses the various injection and detection systems available for gas chromatography. This enables delicate substances to be detected in very small amounts.

    Injection:

    • Liquid
    • Gaseous (dyn. and stat. Headspace)
    • Cool on column
    • Programmable temoperature (PTV)
    • On column
    • Desorption (SPME), TDU, Twister

    Detection:

    • Flame ionisation (FID)
    • Thermal conductivity (TCD)
    • Elektron capture (ECD)
    • Mass spectrometry (MS)

    Download File

    Please enter your contact details and the file will start downloading immediately after your details have been submitted. This only has to be done for the first file you download on this site. Thank you for your understanding.

    Personal Information

    Fast- and Ultrafast-GC are also performed.

    Download File

    Please enter your contact details and the file will start downloading immediately after your details have been submitted. This only has to be done for the first file you download on this site. Thank you for your understanding.

    Personal Information

    Dr. Andreas Grimm
    Dr. Andreas Grimm
    CCA, Chromatography
    +49 69 305 5797

    Request to Clariant

  • coupling

    Analytical coupling techniques enable samples to be measured without isolation („online“). First there is a chromatographic separation. Then a spectroscopic method, such as mass spectrometry or infra-red spectroscopy is used for determination.

    The following techniques are available:

    • LC / HR-MS
    • GC / MS
    • Headspace GC / MS
    • TLC / MALDI or TLC / LD

    Download File

    Please enter your contact details and the file will start downloading immediately after your details have been submitted. This only has to be done for the first file you download on this site. Thank you for your understanding.

    Personal Information

    Dr. Elias Lützen
    Dr. Elias Lützen
    CCA, Structure Elucidation
    +49 69 305 16391

    Request to Clariant

  • Dr. Andreas Grimm
    Dr. Andreas Grimm
    CCA, Chromatography
    +49 69 305 5797

    Request to Clariant

  • Download File

    Please enter your contact details and the file will start downloading immediately after your details have been submitted. This only has to be done for the first file you download on this site. Thank you for your understanding.

    Personal Information


Request to Clariant

Please enter your contact information so we are able to process your request. Thank you for your interest.

Contact Us
Contact Us
Online Communications Team
Disclaimer:
This information corresponds to the present state of our knowledge and is intended as a general description of our products and their possible applications. Clariant makes no warranties, express or implied, as to the information’s accuracy, adequacy, sufficiency or freedom from defect and assumes no liability in connection with any use of this information. Any user of this product is responsible for determining the suitability of Clariant’s products for its particular application.<br />
<br />
* Nothing included in this information waives any of Clariant’s General Terms and Conditions of Sale, which control unless it agrees otherwise in writing. Any existing intellectual/industrial property rights must be observed. Due to possible changes in our products and applicable national and international regulations and laws, the status of our products could change. Material Safety Data Sheets providing safety precautions, that should be observed when handling or storing Clariant products, are available upon request and are provided in compliance with applicable law. You should obtain and review the applicable Material Safety Data Sheet information before handling any of these products. For additional information, please contact Clariant.<br />
<br />
* For sales to customers located within the United States and Canada the following applies in addition: No express or implied warranty is made of the merchantability, suitability, fitness for a particular purpose or otherwise of any product or service.<br />
<br />
© Trademark of Clariant registered in many countries.<br />
® 2019 Clariant International Ltd 

You are about to leave the Clariant domain

The link you activated will take you outside the Clariant site in about 10 seconds. If you want to stop this, press "Cancel".