Resumir
maio 30, 2014

HYTREAT DF 12851A, from Clariant Oil Services, Increases Production and Maintains Water Quality

Energy Oil and Gas

Benefits

  • Minimized downtime following shut-in and cold start, yielding increased production
  • Significant logistics and handling savings due to treatment volume reduction by 60 folds over methanol
  • Decreased contaminating crude oil and produced water positively impacting HSE 

Background

A producer in the Gulf of Mexico began treating one of its wells with Clariant Oil Services‘ HYTREAT DF 12851A, an anti-agglomerant hydrate inhibitor. Based on hydrate modelling, the conditions of the well were high-risk for hydrate formations during start-up and required to be protected from hydrate formations.

During all planned or unplanned shut-ins, it was essential to treat all production fluids that remained in the flowlines, due to the uncertainty of conditions during downtime and in order to prevent hydrate formations once the well restarted.

Innovation and Value Delivered

Fully treating the well with methanol would require a rate of 57 gallons per minute (gpm) for a minimum of three hours for a planned shut-in, or typically for much longer if the shut-in is unplanned and emergent in nature. However, with Clariant Oil Services‘ HYTREAT DF 12851A, a rate of 0.95 gpm on average was sufficient.

Field treatment rates and results can be seen in the chart below.

may_30_2014

Treatment with HYTREAT DF 12851A increased production for the producer due to minimized downtime following a shut-in, as well as provided a more sufficient flow assurance treatment when compared to methanol. Furthermore, HYTREAT DF 12851A decreased contaminating crude oil and produced water.

may_30_2014-2


Read all news
Clariant International
          Clariant International
          Criamos valor quando reconhecemos as necessidades de nossos clientes – fornecendo soluções competitivas e inovadoras. As necessidades dos nossos colaboradores – adotando nossos valores corporativos. As necessidades dos nossos acionistas – alcançando rentabilidade acima da média. E as necessidades do meio ambiente – agindo de maneira sustentável.
          Social
          • Termos de uso
          • Expediente
          • Data protection and privacy
          Copyright © Clariant 2024. Todos os direitos reservados.

          Resumo da página

          close
          Resumo em andamento
          O resumo da página é gerado por IA