Background

An operator in the Raton Basin was experiencing very high levels of hydrogen sulfide (H2S) in a coal bed methane well, making it impossible to sell the produced natural gas. The H2S levels in the well were measuring between 180 ppm and 200 ppm at the well head, causing concerns for the operator and other personnel who were not used to working around sour wells. The operator contacted Clariant Oil Services for a solution that would both decrease the levels of H2S in the coal bed methane well and improve the quality of the natural gas. The system conditions are shown in Table 1.

Table 1: System Conditions

Gas Production 18 MCFD
Water Production 24 BWPD
Production System Coal Bed Methane

Clariant Oil Services Solutions and Value Delivered

After a thorough review and analysis of the well, Clariant Oil Services selected the H2S scavenger SCAVTREAT 1173 for its successful track record in gas applications. Based on the H2S rates at the wellhead, SCAVTREAT 1173 was injected into the meter run before the pipeline at an optimized rate of 6 quarts per day. This treatment rate resulted in a 100% removal of the H2S in the meter run before the pipeline; a third-party contractor collecting gas samples showed H2S levels of just 0.004% in the meter run.

The removal of H2S created a much safer environment for personnel by eliminating the potential risk of exposure. Reduced levels of H2S also minimized the risk of corrosion, as levels were recorded at less than 1 ppm. And the halt in spiked levels of H2S ended the need for compressor down-time, allowing for the continued production of 30 mm/scfd to the pipeline.

This information corresponds to the present state of our knowledge and is intended as a general description of our products and their possible applications. Clariant makes no warranties, express or implied, as to the information’s accuracy, adequacy, sufficiency or freedom from defect and assumes no liability in connection with any use of this information. Any user of this product is responsible for determining the suitability of Clariant's products for its particular application.*Nothing included in this information waives any of Clariant’s General Terms and Conditions of Sale, which control unless it agrees otherwise in writing. Any existing intellectual/industrial property rights must be observed. Due to possible changes in our products and applicable national and international regulations and laws, the status of our products could change. Material Safety Data Sheets providing safety precautions, that should be observed when handling or storing Clariant products, are available upon request and are provided in compliance with applicable law. You should obtain and review the applicable Material Safety Data Sheet information before handling any of these products. For additional information, please contact Clariant.