Skip to main content

Steam reforming is a principal industrial process to manufacture synthesis gas (Syngas) for the production of hydrogenammonia and methanol. The heart of the process is the tubular primary reformer where hydrocarbon feed (e.g. methane) reacts catalytically with steam to a mixture of hydrogen, carbon oxide and carbon dioxide (syngas). Nickel based steam reforming catalysts have been manufactured and marketed by Clariant for over 60 years. 

Performance benefits through superior ReforMax LDP catalysts

Steam Reforming catalysts must satisfy several basic requirements in service, for example high activity, good heat transfer, low pressure drop, low carbon formation, and high physical strength. The performance of the catalyst is not only determined by its shape and its resulting geometric surface area (GSA) but also by the resulting pressure drop in the Reforming tubes.

How ReforMax LDP catalysts benefit you

Based on the performance parameters Clariant developed the ReforMax LDP catalysts series which provide these benefits

Clariant Image Benefits Safe_operation 2920

Safe operation

Due to high mechanical and thermal stability and suppression of carbon formatting 

Clariant Image Benefits Less_wear_and_tear 2020

Less wear and tear

The good heat transfer prevents hot spots at the tubes and thus increases the lifetime of the tubes

Clariant Image Benefits Energy_savings 2020

Energy savings
The low pressure drop in combination with the high activity allows the reduction of Syngas compression energy to save fuel and energy costs

Clariant Image Benefits Capacity_increase 2020

Capacity increase
the high geometric surface area ensures highest activity which minimizes the methane slip. Furthermore the low pressure drop enables a higher throughput

Flow chart

ReforMax® LDP series catalysts are commercially proven to be highly effective for any condition of process feed and process design.

Typical operating conditions Ammonia
Outlet Temperature 760 – 805 °C
Inlet Pressure 20 – 45 bar
Clariant Image Flow_Chart_Ammonia 2020
Typical operating conditions Methanol
Outlet Temperature 840 – 900 °C
Inlet Pressure 20 – 30 bar
Clariant Image Flow_Chart_Methanol 2020
Typical operating conditions Hydrogen
Outlet Temperature 800 – 900 °C
Inlet Pressure 20 – 30 bar
Clariant Image Flow_Chart_Hydrogen 2020