Skip to main content
  • Clariant Logo
  • Compartir
  • Contacto
  • es - US
  • Translate
  • Contrast
  • Buscar
  • Productos y soluciones
  • Sustentabilidad
  • Company
  • Medios de comunicación
  • Investors
  • Careers
  • Events
Cerrar
Buscar
Cerrar
SDS & Document Finder
result(s)
Todos los resultados
Cerrar
Facebook Twitter LinkedIn Correo electrónico WhatsApp More Options
Cerrar
Cerrar
The translation will be performed automatically using AI. Please double-check important facts and statements.
Cerrar
Clariant International
  • Productos y soluciones
  • Sustentabilidad
  • Company
  • Medios de comunicación
  • Investors
  • Careers
  • Events
Inicio / Productos y negocios / Pinturas y revestimientos / Aditivos para pinturas / Extending open time in paints
Additives for Paint
Resumir

Extending the
open time of paints

Enhance the ease of painting with our additives

Driven by the wish to reduce VOC/SVOC in paints, the shift from solvent-based to water-based formulations has made it difficult for formulators to control the period during which irregularities in freshly applied paint can be repaired. With special additives for extending the open time of water-based acrylic and PU paints, as well as cutting-edge testing methods, we help paint makers solve this challenge.

Working with paints that dry too quickly can be frustrating for consumers and professionals alike. The time during which freshly applied coatings remain wet enough to correct brush and lap marks is commonly referred to as open time. It is closely related to workability, i.e. how easily paint can be spread, brushed and layered. Wet edge time, during which overlapping paint layers do not leave visible lap marks, is generally considered part of open time.

Our high-performing dispersing and wetting agents can be used as open time extenders that push the time window for correcting paint films wide open – improving workability, wet edge time, as well as other crucial properties such as gloss, leveling and sagging. What’s more, our experts have developed state-of-the-art methods for assessing how well our additives improve open time, and which best meet your specific needs.

Clariant Brush Teaser 20230609

Controlling open time – by deep-diving into the dynamics of the applied paint

Paints are complex systems due to the large number of additives they contain. After application of the paint onto the wall, dynamics between binder and other ingredients occur that influence the open time and drying time. Our experts have studied the influence of additives on these phenomena of additives using a combination of advance measurements and standard tests including:

  • Self-developed 12-pin geometry to measure paint torque and viscosity change over time
  • Rheolaser measurement of Brownian motion to monitor surface dynamics changes
  • Cross tests and overlapping tests to validate the performance of selected additives that extend the open time of paints

The result is a broad portfolio of accurately tested open time extenders for acrylic and PU lacquers that reliably boost workability and ease of use.

Clariant Laboratory Teaser 20230609

Paint additives extending open time of selected paint systems

 Additive  Ionicity  Suitable for
Acrylic lacquers  PU lacquers 

 Dispersogen™ AN 200

anionic ✔

 Emulsogen™ LCN 158

nonionic ✔
✔

 Emulsogen™ LCN 287

nonionic
✔
✔

 Dispersogen™ LFS

anionic
✔
✔

 Dispersogen™ PL 30

nonionic
✔
✔

 Emulsogen™ LCN 118

nonionic
✔
✔

 Genapol™ O 100

nonionic
✔
  

 Genapol™ O 080

nonionic
✔
 

Want to know more about our open time extenders?

Download our brochure.

  • Brochure Extending Open Time in Paints EN 2023 (0.57 MB)

Descargar archivo

Cerrar

What we can offer you

paint_additives_portfolio

A broad portfolio of additives for extending the open time of acrylic paints and polyurethane-based (PU) lacquers

paint_combining_properties

A combined approach enabling customers to also improve other properties of their paint systems (such as gloss, leveling etc.)

paint_formulation_expertise

Proven expertise and know-how in paint formulation coupled with state-of-the-art, highly accurate testing methods

paint_development_team

A team of experts to support you in the formulation and development of paints

Watch how we assess and measure open time

These short videos show how we use a Rheometer with a specialized geometry and Rheolaser setup to measure open time. They also show two methods to approximately assess open time in the lab, using cross and overlapping tests.


  • Definition of open time

  • Clariant's lab methods

  • Cross Test in coatings

  • Overlap Test

one two three four

Any questions? Get in contact!

Clariant International
          Clariant International
          Creamos valor agregado mediante la apreciación de las necesidades de nuestros clientes: con soluciones competitivas e innovadoras. Las necesidades de nuestros empleados: adhiriéndonos a los valores de nuestra empresa. Las necesidades de nuestros accionistas: con rendimientos superiores al promedio. Y las necesidades de nuestro entorno: actuando de manera sustentable.
          Social
          • Colofón
          • Términos de uso
          • Data protection and privacy
          • General Terms and Conditions of Sale and Purchase
          Derechos de autor © Clariant 2024. Todos los derechos reservados.

          Resumen de la página

          close
          Resumen en curso
          El resumen de la página se genera por IA